This manual provides detailed information on the Cognex In-Sight 7000 series machine vision system, including specifications, installation, configuration, connection, operation, and maintenance.
This manual provides installation and safety guidelines for the Cognex In-Sight 7000 Series vision systems. It includes precautions for electrical safety, environmental hazards, and proper cable handling. The document also covers regulatory compliance, including FCC, KCC, NRTL, and RoHS certifications for various models in the series. Installation procedures are detailed, with specific instructions for C-Mount lens configurations and cable connections.
The system must be supplied by a UL or NRTL listed power supply with a 24VDC output rated for at least 2A continuous and a maximum short circuit current rating of less than 8A and a maximum power rating of less than 100VA.
The white ring light is in Risk Group 1 and it is not recommended to stare directly into the illumination LEDs when the vision system is receiving power.
The bend radius must be at least sixinches from the connector and cannot be tighter than 10X the cable diameter.