This file is the operating manual of magnet valve 0142, which contains product features and characteristics, use instructions, installation instructions, maintenance and maintenance instructions, etc.
This document provides detailed operating instructions for the Bürkert Type 0142 solenoid valve, including safety warnings, installation steps, electrical connections, and maintenance procedures. It specifies technical data such as voltage, material compatibility, and temperature limits. The manual emphasizes safe handling, proper mounting, and regular operation to ensure longevity and prevent hazards.
The valve is designed for controlling neutral and aggressive media up to 21 mm²/s viscosity, with IP65 protection when properly installed. It includes warnings for high-pressure, electrical, and thermal hazards, and advises users to follow all safety precautions during installation, maintenance, and operation. This manual is written in German.
| Material | PVC (PV) or PVDF (PD) |
|---|---|
| Sealing Material | FKM, EPDM |
| Protection Rating | IP65 |
| Operating Temperature | 0°C to +40°C (PVC), 0°C to +55°C (PVDF) |
The housing is made of PVC (PV) or PVDF (PD).
The valve has an IP65 protection rating when properly installed with a Bürkert Type 2508 device plug.