This is an operating manual that introduces the product characteristics and usage methods of the 8011 type flow meter produced by Bürkert SAS.
This manual provides detailed operating instructions for the Bürkert SAS 8011 flow meter, including safety guidelines, installation procedures, electrical wiring, commissioning, and maintenance. It covers technical specifications, fluid compatibility, and troubleshooting for proper device operation. The device is designed to measure flow rates of neutral or slightly aggressive liquids without solid particles, with options for M12 connectors or cable glands. Maintenance must be performed by qualified personnel to avoid injury or damage.
| Ambient temperature | -15...+60 °C |
|---|---|
| Air humidity | < 80%, non condensated |
| Protection class | IP67 (M12 fixed connector), IP65 (cable gland) |
| Pulse output | NPN or PNP |
The device can be wired with a 1 m cable or an M12 fixed connector, with adjustable positioning.
Maintenance must be performed by qualified personnel using appropriate tools, and the system must be safely restarted after any intervention.
The device must be checked for chemical compatibility with fluids such as alcohols, acids, alkaline compounds, ketones, oxidants, and chlorinated agents.