This manual provides detailed instructions on how to install the Electrolux central vacuum system.
This manual provides instructions for installing an Electrolux central vacuum system in both new and existing buildings. It details the optimal location for the power unit, such as utility rooms or the lowest floor in multi-story buildings, and emphasizes the need for sufficient compensation air supply and insulation in cold areas to prevent condensation.
The guide covers the design and installation of the tubing system, specifying dimensions for main tubes and exhaust pipes. It includes specific procedures for installing wall inlet valves using mounting brackets and 90° elbows to prevent blockages, as well as methods for floor installations and routing tubes through brick or concrete walls.
| Tubing System Outside Diameter | 2" (60.08mm) |
|---|---|
| Tubing System Extension Diameter | 2 1/8" (66mm) |
| Wall Through-Hole Diameter | 2 3/16" to 2 1/2" (65mm to 60mm) |
| Minimum Exhaust Tube Diameter | 2 1/8" (66mm) |
| Recommended Hose Length for Coverage | 27 to 33 feet (8m to 10m) |
| Inlet Hole Rectangular Opening Size | 2 3/8" x 4 3/4" (60mm x 110mm) |
It is recommended to always place the power unit on the lowest floor.
The vacuum tubing and the exhaust pipe should be insulated to avoid condensation.
A 90° inlet elbow is used to prevent long objects from entering the tubing system.