This document is SENTINEL BOOM GATE instructions
This manual provides installation instructions for the Rotech Sentinel MB2 boom gate. It details the selection of spring assemblies based on pole length and profile, as well as the specific base plate requirements for different pole sizes.
The guide includes step-by-step procedures for fitting the boom pole, including drilling templates, installing internal and external clamping pieces, and securing the assembly with M10 bolts and nuts. It also covers the attachment of the operating handle and end cap.
| Boom pole profile | 76.2 x 1.27 Aluminium tube |
|---|---|
| Base Plates | 200 150, 160, 100, 200; 240 100) 150 |
The pole can only be locked in the fully open or closed position by screwing the thumb wheel in to unlock and out to lock.
Yes, a padlock can be fitted when the pole is in the closed position for extra security.