Toshiba VF-AS3 Inverter Embedded Ethernet Function Manual

This document is the instruction manual for Toshiba VF-AS3 inverter


Toshiba VF-AS3 Inverter Embedded Ethernet Function Manual - cover page
Brand
Toshiba
Document type
User Manual
Language
English
Pages
84
File format
PDF
File size
2 MB
Published
16 October, 2023
Updated
16 October, 2023
Model
VF-AS3
MD5 checksum
30CB8207E608D55B7CE979D277B35A25

About this manual

The document is an instruction manual for the Embedded Ethernet Function of the Toshiba TOSVERT VF-AS3 inverter. It details specifications for dual RJ45 shielded connectors, supported topologies (daisy chain and star), and network protocols including Modbus TCP and EtherNet/IP.

The guide provides instructions on configuring IP addresses via DHCP or manual settings using the LCD panel guidance function. It also explains LED indicator statuses for link activity and module health, installation topology requirements, and how to access the built-in web server for monitoring and parameter configuration.

What's inside

  • Specification
  • LED indicator
  • Installation Topology
  • Modbus TCP
  • EtherNet/IP
  • Web server

Specifications

Ethernet connectorDual RJ45 shielded connector
Supported topologyDaisy chain topology, Star topology
Supported networkModbus TCP / EtherNet/IP
Command reception timeAbout 5ms
Baud rateAuto negotiation (10/100Mbps, Full/Half duplex)

Frequently asked questions

What is the life of the EEPROM in the VF-AS3?

The Life of EEPROM is approximately 100,000 times.

Can I connect an RS485 cable to the Ethernet port?

No, do not connect RS485 communication cable into Ethernet port as it will result in failure.

What does a flashing red MS LED indicate?

A flashing red MS LED indicates that the device has detected a communication error.

Download PDF (2 MB)