This manual describes the operating and maintenance methods of F.D fan.
This document serves as the operating and maintenance instruction manual for the Hyundai Marine Machinery F.D Fan. It covers safety cautions prior to operation, start-up procedures, and daily operational checks including damper control and bearing temperature monitoring. The guide also details how to handle specific issues such as surging and abnormal vibrations.
The amount of grease required is sufficient when filled and approximately 1/3 for in the bearing case.
The bearing temperature should be kept under 70° under any condition.
Start the blower with the air control damper closed and increase the speed gradually.