NS Bubblizer Rev Sim-11 Maintenance and Parts Manual

This manual introduces the maintenance and maintenance methods of NS company's vehicle washing equipment, including the basic structure of the equipment, maintenance frequency, maintenance methods and precautions, etc.


NS Bubblizer Rev Sim-11 Maintenance and Parts Manual - cover page
Brand
NS
Category
Other
Document type
Service Manual
Language
English
Pages
32
File format
PDF
File size
2.2 MB
Published
16 October, 2023
Updated
16 October, 2023
MD5 checksum
B688D9766A368CC000C45D7E96912AEA

About this manual

This document is the Maintenance & Parts Manual for the NS Bubblizer™ vehicle washing system, specifically Revision Sim-11. It details the system specifications, including two 1.5 HP air motors and PVC plumbing, and provides instructions for installation and operation. The manual includes electrical and plumbing schematics, isometric views of the tank and wax applicator, and specific procedures for the DEMA MixRite chemical metering board.

What's inside

  • System Specifications
  • Schematics
  • Operating Description
  • Installation
  • Wax Applicator
  • DEMA MixRite
  • Troubleshooting
  • Warranty

Specifications

Motor PowerTwo 1.5 HP per unit
Total Amperage14.8 amps
Voltage120VAC
Tank MaterialPowder-coated aluminum
Mounting Base4"x4" square anchor

Frequently asked questions

What type of water should be used in the Bubblizer?

Fresh water must be used; reclaim water will damage internal components.

What is the warranty period for the equipment?

The equipment is guaranteed for one year from installation or 30 days from the invoice date.

What should be done if the MixRite makes scratching noises?

Check if the suction pipe is immersed and not folded, or clean and rinse the suction filter.