This document is the RadiPower® 4000 series RF power meter manual of Raditeq B.V., which mainly introduces the product's usage methods, precautions and other information.
This document is the product manual for the Raditeq RPR4006R, a true RMS power meter designed for EMC measurements. It details the device's theory of operation, which utilizes a hardware RMS detector to measure non-sinusoidal signals accurately without additional signal processing. The manual also describes the included RadiMation software for automated testing and report generation.
| Measuring function | RMS power |
|---|---|
| Measurement speed | 1 MS/s | 5 MS/s |
| Resolution | 0,01 dB |
| Frequency range | 4 kHz to 6 GHz |
| Frequency response accuracy | +/- 0,2 dB |
| Linearity error | 0,05 dB + 0,005 dB/dB |
| Dimensions | 125,2 * 44.5 * 32 mm |
| Supply voltage | +5Vdc from USB port (4,75 V to 5,25 V) |
| Current consumption | Max. 500 mA |
| Operating temperature range | 0° to 30° Celsius |
| Storage temperature range | -10 to 50º C |
| Warranty | 3 year (after registration) |
The measurement speed is 1 MS/s or 5 MS/s.
No, zero adjustment is not required for this device.
The input damage level is greater than +20 dBm.
A three-year warranty is granted only after the product is registered at www.raditeq.com.