The document is Goldline Controls GL-235 Solar Pool Controller Installation and Operation Manual, which introduces the features and characteristics of the product
The document provides installation instructions for the Goldline Controls GL-235 series differential temperature controls used in solar heating systems for pools, spas, and hot tubs. It details requirements for outdoor mounting, power input connections (115VAC or 240VAC), and sensor placement.
| Input Power (LV) | 105-130VAC, 5A 50/60Hz |
|---|---|
| Input Power (HV) | 195-250VAC, .3A 50/60Hz |
| Differential Turn On | 4°F |
| Differential Turn Off | 1.5°F |
| Freeze Protection Temp Range | <40°F to >42°F |
The GL-235 must be mounted a minimum of 5 feet horizontally from the pool or spa.
Install the jumper across both pins marked 'RECIRC' located near the top right of the main circuit board.
Replace with a 2A, type 3AG SLO-BLO fuse.