Winsensor F1012 Micro Flow Sensor Product Manual

This product manual provides a detailed introduction to Winsensor F1012 micro flow sensor's product features, working principle, application areas, flow conversion, technical parameters, etc.


Winsensor F1012 Micro Flow Sensor Product Manual - cover page
Brand
Winsensor
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
5
File format
PDF
File size
572 KB
Published
30 March, 2023
Updated
27 September, 2023
MD5 checksum
CD634449321C71EA9EBD0BE81337BE0F

About this manual

The Winsensor F1012 is a micro flow sensor series utilizing the latest MEMS sensor chip technology. It features no drift or hysteresis, high precision, fast response speed, and good repeatability. The sensor operates using a low-power pulse excitation current and can accurately measure very small flow rates after full calibration and temperature compensation. It offers linear or square root characteristic outputs in either analog or digital formats. This manual is written in Chinese.

What's inside

  • Product Features
  • Working Principle
  • Application Fields
  • Flow Conversion
  • Technical Parameters
  • Model Naming Rules
  • Optional Parts
  • Warranty
  • Disclaimer

Specifications

Measurement Range0-2000 sccm
Full Scale Output4.95-5.05 V
Zero Point Output0.96-1.04 V
Power Supply Voltage7.0-15.0 V
Power Current35-55 mA
Accuracy1.5-2.5 % FS
Repeatability0.3-0.5 % FS

Frequently asked questions

What are the main application fields for this sensor?

The sensor is used in medical equipment, HVAC systems, industrial process control, air and environmental protection, and portable instruments.

How is the actual flow rate calculated?

Actual flow equals full scale multiplied by the difference between sensor output voltage and zero output voltage, divided by the difference between full scale output voltage and zero output voltage.

What is the warranty period for the product?

The product comes with a one-year warranty from the date of manufacture for quality issues caused by design, production, inspection, or transportation.