Emtronix ETA108 Data Acquisition Module Application Manual

This document introduces the features and characteristics of the ETA108 data acquisition module from Emtronix, including support for hardware trigger AD acquisition, low-cost high-performance, 8-channel single-ended input or 4-channel differential input, etc.


Emtronix ETA108 Data Acquisition Module Application Manual - cover page
Brand
Emtronix
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
17
File format
PDF
File size
498 KB
Published
08 February, 2023
Updated
28 September, 2023
MD5 checksum
EAF0A33AFAB8128C818C9077BCA5BA4A

About this manual

This document is the application manual for the Emtronix ETA108 data acquisition module. It describes the module as a low-cost, high-performance AD acquisition unit that supports hardware cycle pulse triggering. The module connects to the mainboard via a simple 4-wire SPI interface and is designed for applications such as waveform recorders, power harmonic analysis, and vibration signal analysis.

The manual details the hardware design, including the 8 single-ended or 4 differential input channels, 12-bit AD conversion accuracy, and maximum sampling speed of 100ksps. It provides specific definitions for the CN1 SPI interface pins and the CN2 analog signal input pins. Additionally, it explains the operating principles, including the multiplexer, programmable gain amplifier (PGA), and SAR ADC, along with instructions for configuring single-ended and differential modes. This manual is written in Chinese.

What's inside

  • ETA108 Introduction
  • Interface Definition
  • Electrical Characteristics
  • Operating Principle
  • Channel Multiplexing
  • Single-Ended Application
  • Differential Application
  • Conversion Results
  • Average Mode
  • Configuration Registers

Specifications

Input Channels8 single-ended or 4 differential
Input Range0~4.096V
AD Conversion Accuracy12bit
Maximum Sampling Speed100ksps
Interface4-wire SPI

Frequently asked questions

What is the main feature of the ETA108 module?

It supports hardware cycle pulse triggering for AD acquisition, making it suitable for high-precision sampling intervals.

How does the ETA108 connect to the mainboard?

It connects via a simple 4-wire SPI interface.

What are the available gain settings for the PGA?

The gain can be set to 1, 2, 4, or 8.

Download PDF (498 KB)