ETCR ETCR3200 Double Clamp Multi-function Grounding Resistance Tester User Manual

The ETCR3200 Double Clamp Multi-function Grounding Resistance Tester is a product that complies with IEC61010 standards. Safety precautions must be taken into consideration when using the tester, including reading the user manual, adhering to safety regulations and precautions, and paying attention to the current direction of the clamp. Touching bare conductors and circuits under measurement is prohibited. Before measurement, ensure that the FUNCTION rotary switch is set within the proper measuring range and that the connector plug of the lead is securely inserted in the tester interface. Avoid applying over 100V A.C. or D.C. voltage on the testing end and interface to prevent damage to the tester. Do not measure in inflammable places to avoid potential explosions. If exposed metal is caused by a broken enclosure or testing wires, stop using the tester. Additionally, avoid storing the tester in high-temperature and moist environments, or where condensation may occur.


ETCR ETCR3200 Double Clamp Multi-function Grounding Resistance Tester User Manual - cover page
Brand
ETCR
Category
Other Electronics
Document type
User Manual
Language
English
Pages
22
File format
PDF
File size
849 KB
Published
03 February, 2023
Updated
28 September, 2023
MD5 checksum
F7DCB0AC408175E2FD42B2F80B72F53F

About this manual

The ETCR3200 is a multi-function grounding resistance tester designed to measure earth resistance using 4-pole, 3-pole, 2-pole, selection, and double clamp methods. It also measures soil resistivity, earth voltage, AC current, and DC resistance. The device features a large LCD with blue backlight, FFT/AFC anti-interference technology, and the ability to store up to 2000 sets of data for upload via RS232 interface.

What's inside

  • Brief introduction
  • Technical specification
  • Structure of tester
  • LCD display
  • Principle of measurement
  • Operation Methods
  • Battery Replacement

Specifications

Power SupplyDC 9V (6 x R14S 1.5V)
Measuring Range (Earth Resistance)0.00 Ω-29.99 Ω / 30.0 Ω-299.9 Ω / 300Ω-2999 Ω / 3.00k Ω-30.00k Ω
Intrinsic Error (Earth Resistance)±2%rdg ±5dgt
Data Storage Capacity2000 sets
Measuring Rate (Earth Resistance)about 7 seconds/time

Frequently asked questions

How many sets of data can the ETCR3200 store?

The device can store up to 2000 sets of data.

What is the intrinsic error for earth resistance measurement in the 0.00 Ω-29.99 Ω range?

The intrinsic error is ±2%rdg ±5dgt.

What happens when the battery voltage decreases to about 7.5V?

A battery voltage low icon will display on the screen to remind the user to replace the battery.