This document is the user manual for PMC232 series v0.03, providing instructions on IO usage and settings, interrupts, etc.
The document serves as a user guide for the PADAUK PMC232 Series microcontrollers. It focuses on practical usage tips to prevent common errors by users new to the device. Key topics include configuring Input/Output (IO) pins for analog or digital functions, setting up interrupt handlers, and managing system clock sources like ILRC, IHRC, and EOSC. This manual is written in Chinese.
| Minimum VDD for Power On | 2.2V |
|---|---|
| Recommended Max ADC Conversion Frequency | 500kHz |
The VDD must exceed 2.2V for successful startup.
No, only FPPA0 can use interrupts (ENGINT and DISGINT).
The recommended maximum conversion frequency is 500kHz.