This document is a service manual for 1/64 i-mop xxl, including instructions for use, safety information, machine description, scheduled maintenance, and component replacement.
This service manual provides technical details and repair instructions for the Tennant 1/64 i-mop xxl floor scrubber. It covers general information, safety symbols, and machine description including technical characteristics such as voltage, tank capacities, and motor specifications. The document outlines scheduled maintenance plans and detailed replacement instructions for various components, including brush motors, magnetic valves, mainboards, levers, dashboards, tubes, vacuum motors, wheels, filters, and squeegee wheels. It also includes water safe interval adjustment, electrical schemes, battery information, and charger datasheets.
| Voltage | 24 V |
|---|---|
| Washed track | 64 cm |
| Vacuum | 5.8 kPa |
| Solution tank capacity | 5 L |
| Recovery tank capacity | 5L |
| Disc brush speed | 350 rpm |
| Number of disc brushes | 2 |
| Disc brush pressure | 24.6 kg |
| Maximum floor slope for using the machine | 6% |
| No. of batteries | 2 |
| Theoretical hourly yield | 2300 m2 |
| Estimated hourly yield | 1700 m2 |
| Autonomy | 70 min |
| Width of machine passage | 64 cm |
| Machine body dimensions | 43x124x69 cm |
| Machine weight empty | 21 kg |
| Machine weight heavy | 35.3 kg |
| Disc brush motor power | 170 W (x2) |
| Vacuum motor power | 180 W |
| Protection class | IP2X |
| Sound pressure level A | 76 dB(A) |
| Sound power level A | 74 dB(A) |
| Charger Input voltage | AC 100-240 V |
| Charger Frequency | 50-60 Hz |
| Charger Output current | 9A |
| Charging voltage | 29.4 V |
| Float voltage | 27.4 V |
| Charger Weight | 1.125 kg |
The usage temperature of the machine must be between 0°C and +40 °C.
The storage temperature of the machine must be between 0°C and +40 °C.
The humidity must be between 30% and 95%.
The maximum floor slope for using the machine is 6%.