This document is an instruction manual for the use and installation of a reverse osmosis drinking water machine. It mainly introduces the precautions for use, installation methods, and usage instructions of the product, and provides a website for barcode verification. This reverse osmosis drinking water machine is suitable for mainland China and is not suitable for use overseas. It needs to be installed by professionals, and special user groups need to use it under adult supervision.
This document is the user and installation guide for Rinnai RWTS-BR series reverse osmosis (RO) drinking water machines. It covers product functions, specifications, structure, control interface details, installation procedures, usage instructions, network configuration, fault diagnosis, safety precautions, and warranty information. This manual is written in Chinese.
| Rated Net Water Flow | 0.2 L/min (RWTS-BR75) / 0.27 L/min (RWTS-BR100) |
|---|---|
| Rated Total Net Water Volume | 2000 L |
| Rated Power | 1550 W (RWTS-BR75) / 1850 W (RWTS-BR100) |
| Power Supply | ~220V, 50Hz Single-phase AC |
| Waterproof Rating | IPX4 |
| Inlet Water Pressure | 0.1~0.4 MPa |
| Working Pressure | 0.4~0.8 MPa |
| Applicable Water Temperature Range | 5~38 ℃ |
| Hot Water Outlet Temperature | 45~99 ℃ (Adjustable) |
| Gross Weight / Net Weight | 25kg/33kg (RWTS-BR75) / 27kg/35kg (RWTS-BR100) |
| Product Dimensions | 400mm x 425mm x 1400mm |
No, the machine is not suitable for outdoor installation or use in places where water splashing may occur.
The water purifier must be installed by professional personnel.