This document describes the application and characteristics of the 606 adjustable setpoint gas differential pressure switch, including technical specifications, installation methods, and precautions.
This manual provides instructions for the Teren 606 Adjustable Setpoint Gas Differential Pressure Switch, which is used to monitor overpressure, vacuum, and differential pressure states for non-flammable, non-corrosive gases like air. The device features a selectable range of four scales and supports SPDT output with silver alloy or gold-plated contacts. This manual is written in Chinese.
| Maximum Pressure Limit | 7500Pa |
|---|---|
| Operating Temperature | -30~75°C |
| Switch Life | 106 times |
| Output | SPDT, 0.2A/30VDC, 1.5A/250VAC |
| Maximum Switch Frequency | 6 times/minute |
| Protection Rating | IP54 |
It is suitable for monitoring non-flammable, non-corrosive gases such as air.
The switch should be installed vertically with the pressure ports facing down to allow moisture to drain.
The maximum working differential pressure is 7500Pa; exceeding this may damage the switch.