ETCR 010KD Openable DC Leakage Current Sensor User Manual

ETCR 010KD is a closed-loop DC leakage current sensor, suitable for high-precision DC leakage current and DC small current online detection. It adopts closed-loop CT technology, with double-layer shielding, portable and online installation. It can be connected to industrial control devices, data loggers, oscilloscopes, high-precision digital multimeters, etc. It is widely used in fields such as power, communication, meteorology, railways, oil fields, construction, measurement, research and teaching institutions, and industrial and mining enterprises.


ETCR 010KD Openable DC Leakage Current Sensor User Manual - cover page
Brand
ETCR
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
2
File format
PDF
File size
235 KB
Published
21 October, 2022
Updated
28 September, 2023
MD5 checksum
B211119726325A228511D1F10B6C88F6

About this manual

The ETCR 010KD is an openable closed-loop DC leakage current sensor designed for high-precision online detection. It utilizes openable CT technology with double-layer shielding to allow safe, non-contact measurement of wires up to 10mm in diameter without disconnecting the circuit. This manual is written in Chinese.

What's inside

  • Safety Precautions
  • Introduction
  • Specifications
  • Principle and Structure

Specifications

FunctionDC leakage current, DC small current detection
Detection MethodOpenable CT, online installation
Power Supply9VDC±1VDC (or optional ±12VDC/±5VDC)
Range0.0mA~100mA DC
Resolution0.1mA DC
Accuracy±3.0%FS
Turns Ratio1:800
Output Signal (9V)25mV/1mA (0-2.5V full scale)
Response Speed2 times/second
Operating Temperature-10℃~45℃

Frequently asked questions

Does this sensor require disconnecting the circuit for installation?

No, it supports online installation without disconnecting the tested line.

What is the maximum wire diameter that can be measured?

The sensor clamp opening allows wires up to 10mm in diameter.

Can it measure ground wire leakage current?

Yes, clamping only the DC system ground wire measures that line's leakage current.