Eurotech ET5101 Smoke/Gas Analyzer User Manual

ET5101 Smoke/Gas Analyzer is a product manufactured by Shanghai Eurotech Instrument Co., Ltd. It uses embedded industrial computer and high-precision sensors to measure exhaust gas parameters and achieve isokinetic sampling. The instrument features high accuracy, dynamic flow rate tracking, and reduced workload.


Eurotech ET5101 Smoke/Gas Analyzer User Manual - cover page
Brand
EuroTech
Category
Industrial Supply
Document type
User Manual
Language
Chinese
Pages
23
File format
PDF
File size
5.3 MB
Published
19 October, 2022
Updated
27 September, 2023
MD5 checksum
0C864EE5CC858F8DA8D26B2373773C09

About this manual

The Eurotech ET5101 Smoke/Gas Analyzer is a portable instrument designed for measuring particulate matter and gas components in flue gas. It utilizes a filter weighing method for dust measurement and electrochemical sensors for gas analysis, featuring an embedded industrial computer and a touch screen interface for dynamic flow tracking and equal-speed sampling.

The manual details the instrument's features, including its ability to measure up to six gas sensors, store 8000 data groups, and operate in temperatures as low as -40°C. It covers operational procedures such as startup, sampling setup, data querying, and calibration, as well as maintenance and troubleshooting guidelines. This manual is written in Chinese.

What's inside

  • General Introduction
  • Operating Principles
  • Instrument Features
  • Specifications
  • Work Environment
  • Operation Preparation
  • Sampling Setup
  • Gas Measurement
  • Maintenance
  • Troubleshooting

Specifications

Sampling Flow Rate5 ~ 60 L/min
O2 Measurement Range0 ~ 20.9%
SO2 Measurement Range0 ~ 2000 ppm
NO Measurement Range0 ~ 1000 ppm
NO2 Measurement Range0 ~ 100 ppm
CO Measurement Range0 ~ 2000 ppm
Storage Capacity8000 groups
Operating Temperature-30 ~ 50 C
Operating Humidity0 ~ 95% RH

Frequently asked questions

What is the measurement principle for dust?

The instrument uses the filter weighing method, where smoke is drawn through a filter tube and the weight difference before and after collection is used to calculate dust concentration.

How does the instrument measure moisture content?

It uses the dry-wet bulb method, calculating moisture content based on the readings of dry and wet bulb thermometers and exhaust pressure.

What gases can the ET5101 measure?

The analyzer can measure O2, SO2, NO, NO2, and CO, with the capability to expand to support up to 6 gas sensors.

What is the maximum storage capacity of the device?

The device has a large capacity memory that can store 8000 groups of data.

Download PDF (5.3 MB)