This document introduces the features and parameters of G64 high-voltage vacuum relays. The relay is compact in design and can withstand voltages up to 35KV. It is completely sealed and can be used for several years. It can be filled with SF6 gas and is suitable for pulse discharge. The high-voltage insulated lead is easy to connect and can be customized in length according to user requirements. Furthermore, this relay does not have contact bounce issues.
The Glvac G64 series of high-voltage vacuum relays are designed with a compact structure and can withstand voltages up to 35KV. They feature a completely sealed design suitable for use over several years and utilize SF6 gas filling to handle pulse discharge effectively.
These relays eliminate contact bounce issues and offer insulated high-voltage leads that can be customized to user requirements. The document provides detailed technical parameters for three models (G64A, G64B, and G64C), covering electrical ratings, mechanical life, coil specifications, and environmental operating conditions. This manual is written in Chinese.
| Maximum Test Voltage (DC or 60Hz) | 55 kV Peak |
|---|---|
| Maximum Operating Voltage (DC or 60Hz) | 50 kV Peak |
| Maximum Continuous Load Current (DC or 60Hz) | 10 Amps |
| Coil Breakdown Voltage (60Hz, RMS) | 500 V |
| Mechanical Life | 1 Million cycles |
| Operating Temperature Range | -55 ~ +85 °C |
The maximum test voltage (leakage current not exceeding 15μA, DC or 60Hz) is 55 kV Peak.
The G64A and G64B models have SPST (Single Pole Single Throw) contacts, while the G64C model has SPDT (Single Pole Double Throw) contacts.
The relays have a mechanical life of 1 million cycles.