HX21 is a small contactor used for 1000+Vdc switches. It is designed to meet UL508 specifications and is rated for load disconnect of 1000Vdc systems. It features the specialized EPIC® Seal ceramic sealing technology, exceeding IP67-69 specifications and providing arc-free operation in open environments. HX21 is the perfect choice for solar, photovoltaic, inverter systems, batteries, junction boxes, DC arc fault switches, or any other high voltage DC systems. It has a high-efficiency DC dual coil with very low power consumption of 12, 24, or 48VDC, without electromagnetic radiation or interference with system control circuits. HX21 is installed in a standing position with an integrated safety cover for contact protection. The product is designed and manufactured in the United States.
The GLVAC HX21 is a compact DC contactor designed for switching systems rated at 1000+Vdc. It features a dedicated EPIC Seal ceramic sealing technology that exceeds IP67-69 specifications, ensuring no exposed arcs in open environments. The device is designed to meet UL508 specifications for load break on rated 1000Vdc systems and UL1604 standards for use in Class I, II, and III hazardous locations. This manual is written in Chinese.
| Contact Form (Main) | Form X Single Pole Single Throw - Normally Open |
|---|---|
| Mechanical Life | 1,000,000 cycles |
| Contact Resistance (Max) | 0.4 mohms |
| Operating Time (Max) | 20 ms |
| Insulation Resistance | 100 Mohms |
| Dielectric Withstand Voltage | 4,300 VRMS |
| Operating Temperature Range | -55 to +85 ˚C |
| Storage Temperature Range | -70 to +150 ˚C |
| Weight | 0.44 Kg (0.98 Lb) |
No, the DC coil has a built-in coil suppressor, so no additional diode is needed.
The current carrying capacity should be limited to below 600A to avoid contact welding.
Yes, it is designed for Class I and II, Division 2 and 3 hazardous areas according to UL1604.