Bühler Technologies BA 2000 BC550012 Smoke Gas Oxygen Analyzer Installation and User Manual

The BA 2000 smoke gas oxygen analyzer is a device used to measure oxygen concentration. It features an automatic temperature control heating element with a temperature of approximately 180°C and uses a zirconia sensor for measurement. It provides accurate measurement and sensitive response.


Bühler Technologies BA 2000 BC550012 Smoke Gas Oxygen Analyzer Installation and User Manual - cover page
Brand
Bühler technologies
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
30
File format
PDF
File size
5.1 MB
Published
28 September, 2022
Updated
28 September, 2023
MD5 checksum
7504F73BEF1EE2F64F92668924B51A43

About this manual

The Bühler Technologies BA 2000 BC550012 is a smoke gas oxygen analyzer that measures oxygen concentration using a zirconia sensor. The device features an automatic heat source in the sampling probe to prevent condensation and does not require reference gas. It is designed for industrial applications where accurate oxygen measurement is critical.

This document provides comprehensive instructions for the safe installation and operation of the analyzer. It details the requirements for transport and storage, step-by-step installation procedures including pneumatic and electronic connections, calibration methods (1-point and 2-point), and operational controls. Additionally, it covers routine maintenance tasks such as filter replacement and troubleshooting common faults. This manual is written in Chinese.

What's inside

  • Introduction
  • Important Safety Instructions
  • Product Description
  • Transport and Storage Requirements
  • Installation and Connection
  • Calibration
  • Operation
  • Maintenance
  • Faults and Elimination
  • Repair and Disposal

Specifications

Measurement PrincipleZirconia sensor
Operating Temperature Range-20°C to +60°C
Sampling Air Pressure Limit0.5 bar
Sampling Tube Diameter6 mm or 1/4 inch

Frequently asked questions

Does the BA 2000 require reference gas for calibration?

No, the zirconia sensor does not require any reference gas.

What is the recommended maximum pressure for instrument air?

The instrument air pressure should be controlled to not exceed 0.5 bar.

Can the device be used in potentially explosive environments?

No, the device is not suitable for use in potentially explosive environments.