TB600C-NO2-100 is a nitrogen dioxide sensor module that uses the German EC Sense solid-state polymer sensor. It features high accuracy, fast response, zero drift, and is suitable for high-precision environmental monitoring, indoor parking nitrogen dioxide pollution monitoring, and other applications.
The EC Sense TB600C-NO2-100 is a Nitrogen Dioxide (NO2) gas detection module designed for environmental monitoring applications such as indoor parking lots and gas leak detection. It utilizes German solid-polymer electrochemical sensor technology to provide high precision, fast response times, and low power consumption.
The module features a UART digital signal output that simplifies integration by eliminating the need for complex calibration or user knowledge of sensor application. Key characteristics include an independent temperature and humidity digital sensor combined with intelligent algorithms for enhanced environmental adaptability, along with strong anti-interference capabilities suitable for IoT applications. This manual is written in Chinese.
| Detected Gas | Nitrogen Dioxide (NO2) |
|---|---|
| Detection Range | 0-100ppm |
| Resolution | 0.1ppm |
| Minimum Detection Limit | 1ppm |
| Accuracy Error (Typical) | ±5% F.S. |
| Response Time | <3 seconds |
| Zero Return Time | <120 seconds |
| Output Signal | 3.3V UART Digital |
| Operating Voltage | 3.3-5.5V DC |
| Working Current | <5mA |
| Operating Temperature | 0 - 40℃ |
| Board Size (with sensor) | 23 x 25.5x10.2mm |
The module detects nitrogen dioxide gas in a range from 0 to 100ppm.
The standard output is a 3.3V level UART digital signal.
No, it uses a UART digital output which eliminates the need for complex calibration work.