About this manual

The BCHP A-10 is a fully automatic air source generator designed to provide stable, dry, and pure compressed air. It utilizes a large-flow oil-free oscillating piston compressor combined with unique self-cooling drying technology and multi-stage purification. This makes it an ideal replacement for high-pressure air cylinders, suitable for use with various analytical instruments such as gas chromatographs, atomic absorption analyzers, and evaporative light scattering detectors.

The document covers the complete user lifecycle of the device, including unboxing checks, self-testing procedures, and daily usage instructions. It details the instrument's components, working principles, key technical parameters (such as flow rate up to 10L/min and pressure stability), and maintenance requirements like filter replacement. This manual is written in Chinese.

What's inside

  • Company Introduction
  • Product Overview
  • Instrument Parts Names
  • Installation and Usage
  • Working Principle and Features
  • Main Technical Parameters
  • Equipment Contents
  • Manufacturer Guarantee
  • Circuit Diagrams

Specifications

Output Flow Rate0-10L/min (at 0.4MPa)
Output Pressure Range0-0.5MPa
Pressure Stability<0.003MPa
Operating Temperature5-40℃
Relative Humidity≤85%
Power Consumption550W
Working Voltage220V±10%V
Air Tank Capacity8L

Frequently asked questions

What is the maximum air flow rate of the BCHP A-10?

The instrument can provide a maximum output flow of 10L/min under 0.4MPa conditions.

How often should the activated carbon filter be replaced?

The activated carbon filter should be replaced once a year.

Does this air source require oil lubrication?

No, the BCHP A-10 uses an oil-free compressor and strictly prohibits adding oil for lubrication.