Yokogawa EJA130E/Z High Static Pressure Differential Transmitter Specifications Sheet

The EJA130E/Z high static pressure differential pressure transmitter is a sensor used to measure the flow, level, density, and pressure of liquids, gases, or steam. It adopts single crystal silicon resonant sensor technology and is mainly used for differential pressure measurement in centrifuges, compressor lubrication systems, and filters in petrochemical and power enterprises. It is also suitable for differential pressure measurement in blowers, pharmaceutical factories, HVAC systems, air velocity, furnace pressure, orifice plates, etc.


Yokogawa EJA130E/Z High Static Pressure Differential Transmitter Specifications Sheet - cover page
Brand
YOKOGAWA
Document type
Product Leaflet
Language
Chinese
Pages
4
File format
PDF
File size
2.8 MB
Published
13 September, 2022
Updated
28 September, 2023
MD5 checksum
754546D3A1C915375ABEA2ABABC4BAC4

About this manual

This document provides technical specifications for the Yokogawa EJA130E/Z industrial differential pressure transmitter. It lists key parameters including a maximum working pressure of 41.3 MPa (6000 psi) and specifies that the process interface complies with IEC61518 standards.

The text details various configuration options such as measuring ranges, process connection types, and material codes for wetted parts and fasteners. It also includes notes on dimensional changes based on specific installation and specification codes. This manual is written in Chinese.

What's inside

  • EJA130E/Z Specifications
  • Maximum Working Pressure
  • Process Interface Standards
  • Wetted Material
  • Measuring Range Codes
  • Process Connection Types
  • Bolt and Nut Materials
  • Specification Codes
  • Installation Code Notes
  • Explosion Proof Type

Specifications

Maximum Working Pressure (MWP)41.3 MPa (6000 psi)
Process Interface StandardIEC61518
Measuring Range Codes (Membrane)M, H, Z
Process Connection Types3, 4, 5

Frequently asked questions

What is the maximum working pressure of this transmitter?

The maximum working pressure is 41.3 MPa (6000 psi).

Which standard does the process interface comply with?

The process interface complies with IEC61518 standards.

Download PDF (2.8 MB)