This document is an installation, operation, and maintenance manual for the Kwik-Change™ Zero Waste Reverse Osmosis System model PWROKCZRO. It provides information on operational parameters, system contents, and installation steps.
The document provides comprehensive instructions for installing the Watts Kwik-Change™ Zero Waste Reverse Osmosis (RO) system. It details operational parameters such as temperature ranges (40°F to 100°F), pressure limits, and pH levels, along with specific steps for drilling sink holes in porcelain or stainless steel sinks and connecting tubing using quick-connect fittings.
The guide outlines a three-stage filtration process involving a carbon block filter, an RO membrane, and a post-carbon filter. It includes maintenance schedules recommending the replacement of the carbon block filter every 6 months, the GAC filter annually, and the membrane every 2-5 years. Troubleshooting advice and parts lists are also provided.
| Operating Temperature Maximum | 100°F (37.8°C) |
|---|---|
| Operating Temperature Minimum | 40°F (4.4°C) |
| Operating Pressure Maximum | 85psi (6.0 kg/cm2) |
| Operating Pressure Minimum | 40psi (2.80 kg/cm2) |
| Maximum pH Level | 11 |
| Minimum pH Level | 2 |
| Maximum Iron Content | 0.2 ppm |
| Maximum TDS | < 1800 ppm |
The carbon block filter should be changed every 6 months.
The membrane is recommended to be changed every 2-5 years.