AMX UPC20+ Universal Power Controller Operation/Reference Guide

This document provides the operation/reference guide for the AMX UPC20+ Universal Power Controller. It includes warranty and disclaimer information for the product.


AMX UPC20+ Universal Power Controller Operation/Reference Guide - cover page
Brand
AMX
Category
Industrial Supply
Document type
User Manual
Language
English
Pages
21
File format
PDF
File size
293 KB
Updated
28 September, 2023
MD5 checksum
CF1EEB12C250182165C3BCE65AC1E328

About this manual

The AMX UPC20+ Universal Power Controller is a dual 20 Amp AC power and motor controller designed for conduit installation. It features a compact metal wall-mount enclosure and is configurable for various power and motor control modes using low voltage contact-closures, open collector inputs, or serial data from an AMX IR receiver. The unit includes local test switches with LED indicators and a user-adjustable timing potentiometer for motor control applications.

What's inside

  • Wiring Requirements
  • Product Information
  • Specifications
  • Control Options Modes
  • Motor Control mode
  • Power Control mode
  • Remote Sensor Control mode
  • Installation
  • Terminal Connections
  • High Voltage Wiring Options

Specifications

Power input (for control board)120/240V ~, 50-60 Hz, 0.05/0.025A -or- 12 VDC, 0.2A max
Power output per relay20A @ 120/240V ~, 50-60 Hz (RESISTIVE LOAD)
Maximum operating ambient temperature55°C
Total Current through both relaysCAN NOT exceed 20 amp
Enclosure dimensions8.5" (10.5" including flange) x 4.5" x 2.2"

Frequently asked questions

What is the warranty period for the UPC20+?

AMX Corporation warrants its products to be free of defects in material and workmanship for three (3) years from the date of purchase.

Who must wire the UPC20+ in the United States?

In the United States, the UPC20+ must be wired by an authorized electrician in accordance with the National Electrical Code.

What is the range for the motor time delay potentiometer?

The timing adjustment potentiometer is user adjustable for automatic release of the relays with a range of 0 to 90 seconds.