STMicroelectronics L6611 Digitally Programmable Secondary Housekeeping Controller Datasheet

L6611 is a digitally programmable secondary housekeeping controller from BCD TECHNOLOGY. It has OV/UV detection, AC mains UV (brownout) detection, online digital trimming, digitally selectable options, error amplifiers, main supply on/off control and power good signal, 50mA crowbar drive for auxiliary output OVP, open ground protection, 8ms digital soft start and 64 ms UV/OC blanking at start-up.


STMicroelectronics L6611 Digitally Programmable Secondary Housekeeping Controller Datasheet - cover page
Brand
STMicroelectronics
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
28
File format
PDF
File size
598 KB
Published
09 August, 2012
Updated
30 September, 2023
MD5 checksum
8EE756078A4E065A1BE9559016BC05DE

About this manual

The L6611 is a control and housekeeping IC developed in BCD technology, intended for acting at the secondary side of desktop PC's or server's switching power supplies. It monitors standard voltage rails (+3.3V, +5V, +12V) and an auxiliary supply line, sending feedback signals to primary controllers and reporting faults like undervoltage (UV) or overvoltage (OV).

A key feature of this IC is its digital programming capability that enables accurate trimming of output voltage rails during production test via software, without external discrete trimming components. It also allows selection of how UV and OC conditions are handled in the main converter, either in latched-mode or bouncing-mode.

What's inside

  • Description
  • Pin Connection
  • Pin Description
  • Function Description
  • Ordering Numbers
  • Typical Application Circuit
  • Block Diagram

Specifications

TechnologyBCD technology
Monitored Rails+3.3V, +5V, +12V
UV/OC Blanking Time64 ms
Soft Start Time8 ms
Crowbar Drive Current50mA
Power Good Delay250ms
PS-ON Delay2.5ms
Vdd Supply SourceAuxiliary power supply output voltage

Frequently asked questions

What is the main function of the L6611?

The Housekeeping's main function is to control and monitor the voltages generated by both the main and the auxiliary converter.

How is the L6611 programmed?

It is programmed via software by forcing the PROG pin high (+5V), which disconnects normal functionality and enables DATA and CLOCK inputs.

What are the two operating modes for UV and OC conditions?

The modes are latched-mode, where information is latched and released only by forcing a restart, and bouncing-mode, which attempts to automatically restart the converter after a 1-second wait.

Download PDF (598 KB)