Texas Instruments ADS1208 2nd-Order Delta-Sigma Modulator Datasheet

ADS1208 is a 2nd-order ∆Σ analog-to-digital converter (ADC) from Texas Instruments. It operates at a clock rate of 10MHz and has a specified input range of ±100mV. It is optimized for current measurement with a Hall sensor, especially in motor control applications.


Texas Instruments ADS1208 2nd-Order Delta-Sigma Modulator Datasheet - cover page
Brand
Texas Instruments
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
22
File format
PDF
File size
353 KB
Published
08 August, 2012
Updated
30 September, 2023
MD5 checksum
F138E80BF0AEF9666B5A774662F47637

About this manual

The ADS1208 is a 2nd-order delta-sigma modulator operating at a 10MHz clock rate, optimized for current measurement with Hall sensors, especially in motor control applications. It features a specified input range of +/-100mV and includes a programmable current source for sensor biasing.

What's inside

  • Features
  • Applications
  • Absolute Maximum Ratings
  • Recommended Operating Conditions
  • Electrical Characteristics
  • Timing Characteristics
  • Device Information
  • Terminal Functions
  • Functional Block Diagram

Specifications

Resolution16 Bits
Full-scale range125 mV
Common-mode rejection95 dB
Output current1.0 to 8.0 mA
Reference output voltage2.5 V
Operating supply current (Mode 3)1.3 to 2.0 mA

Frequently asked questions

What is the specified input range of the ADS1208?

The specified input range is +/-100mV.

What are the main applications for the ADS1208?

It is optimized for current measurement with Hall sensors, especially in motor control applications.

What is the operating clock frequency for Mode 3?

The external clock frequency for Mode 3 ranges from 1.0 MHz to 24.0 MHz.