This is an instruction manual for SEW-EURODRIVE MOVITRAC® 31.. FRS 31 Synchronous Operation Control.
This manual covers the FRS 31 Synchronous Operation Control package, which enables a group of asynchronous motors to maintain angular synchronism. It details the function's eight modes, including free-running, restricted free-running, and synchronous operation with angular offsets. The document explains the principle of continuous angular position comparison between master and slave motors fitted with encoders.
It enables a group of asynchronous motors to maintain angular synchronism with one another or at a specified proportional ratio.
The slave drive must be fitted with a braking resistor to allow synchronous operation of the master and slave.
Up to 10 slaves can be connected to one master for applications like multi-column hoists or travel drives.