This application note introduces STMicroelectronics' SLIC protection solutions for both traditional and new networks.
This document provides an application note on Subscriber Line Interface Circuit (SLIC) protection for both classical and new network topologies. It addresses disturbances caused by atmospheric effects and 50/60 Hz mains networks, referencing standards such as ITU-T K20 and IEC 61000-4-5. The text details the protection needs for long lines using copper twisted pairs and short lines using digital supports like optical fibers.
The document states that an optimized value of 220 nF should be used for this capacitor.
The gate pin voltage must be set within a range of 0 to -175 V.
The actual current flowing through the device is calculated to be 25 A.