This document is the installation instructions for Hayward R, including water safety instructions, electrical specifications, product specifications, electrical safety instructions, etc.
This document provides installation instructions for Hayward pool and spa control systems, specifically the PSC2201 Control Center, PSC2202 Control Center with Breaker Base, and PSC2223 Master Panel. It covers essential safety precautions regarding water and electrical hazards, along with detailed specifications for the included components and optional kits.
| Valve Actuators Output | 0.75A max @ 24 vac |
|---|---|
| Heater Output | 1A max @ 24 vac |
| Relay Contacts Rating | 25A max @ 120 / 240 vac |
| Short Circuit Rating (120V) | 1-1/2 HP max @ 120 vac |
| Short Circuit Rating (240V) | 3 HP max @ 240 vac |
| Tungsten Rating (120V) | 1500 Watts max @ 120 vac |
| Water Temperature Sensor Cable Length | 25' |
| Valve Actuator Power Cable Length | 10' |
The water in a spa should never exceed 104° F (40°C).
Pregnant women should limit spa water temperatures to 100° F (38°C).
The Main Control Center must be installed at least 5' (1.5m) from the inside wall of the pool or spa.