Jandy AquaLink RS PDA Pool Digital Assistant Owner's Manual

This document provides information about the AquaLink® RS PDA - Pool Digital Assistant H0572300D operation data owner's manual, emphasizing that the product must be installed and serviced by a professional pool/spa service technician to avoid property damage, serious injury, or death. The document also mentions the device's compliance with FCC rules and its handling of radio interference.


Jandy AquaLink RS PDA Pool Digital Assistant Owner's Manual - cover page
Brand
Jandy
Category
Other
Document type
User Manual
Language
English
Pages
43
File format
PDF
File size
3 MB
Published
09 July, 2012
Updated
29 September, 2023
MD5 checksum
7F7EEA20DA0E9EF13C8D94E37D240355

About this manual

This document serves as the Owner's Manual for the Jandy AquaLink® RS PDA Pool Digital Assistant. It details the installation requirements, safety warnings, and operational procedures for the handheld remote control used to manage pool and spa systems.

The manual explains how to use the remote's buttons to control various equipment functions, including filters, heaters, pumps, and lighting. It also covers programming automatic schedules, setting temperatures, and navigating through different system menus such as Service, Diagnostics, and System Setup.

What's inside

  • Important Safety Instructions
  • Overview of the PDA Handheld Remote
  • Using the Equipment On/Off Menu
  • Using the Equipment On/Off Model Specific Menus
  • Using the Menus
  • Using the System Setup Menu
  • Glossaries
  • PDA Handheld Remote Menu Flow Chart

Frequently asked questions

What is the maximum safe water temperature for a healthy adult in a spa?

Water temperatures between 100°F (38°C) and 104°F (40°C) are considered safe for a healthy adult.

What is the minimum distance required for Canadian installations from the water?

Canadian installations must be at least three (3) meters from the water.

What is the minimum wire size required for the grounding conductor?

The grounding conductor must be no smaller than no. 12 AWG (3.3mm).