Power Ocean F14xxB Series Filter User Manual

This document introduces the F1443B (V1.0) 10525 product from Shenzhen PowerOcean Technology Co., Ltd. It is a universal low-pass and band-pass active filter IC module suitable for low-frequency analog signal detection in industrial signal detection and medical electronic bio-signal detection. Its features include built-in high-precision capacitors, can be used to construct active high-order low-pass and band-pass filters, and are easy to design and use.


Power Ocean F14xxB Series Filter User Manual - cover page
Brand
F14xxB
Document type
User Manual
Language
Japanese
Pages
6
File format
PDF
File size
177 KB
Published
16 March, 2012
Updated
29 September, 2023
MD5 checksum
68D5E80A56EB9763CA6F3CF80F83F0F0

About this manual

This manual describes the F14xxB series active filters, which are designed for ultra‑low‑frequency applications such as biomedical signal acquisition and precision instrumentation. It covers low‑pass, high‑pass, and band‑pass configurations with selectable cutoff frequencies from 0.1 Hz up to several megahertz.

The document includes detailed technical specifications, package dimensions, pin assignments, design equations for setting cutoff frequencies, and example circuits. It also provides tables of component values for Butterworth, Chebyshev, and other filter prototypes. This manual is written in Japanese.

What's inside

  • Overview
  • Applications
  • Package Dimensions and Pin Assignment
  • Technical Specifications
  • Operation Method
  • Operation Example

Specifications

Frequency range0.1 Hz – 1 MHz
Accuracy1 % (30 ppm/°C)
Supply voltage (Vsup)4 V – 18 V
Operating temperature range0 °C – 70 °C (C銀), -40 °C – 85 °C (1銀), -35 °C – 125 °C (M銀)
Gain1

Frequently asked questions

What frequency range does the F14xxB filter cover?

The filter operates from 0.1 Hz up to 1 MHz, covering ultra‑low to high frequencies.

How is the cutoff frequency for a low‑pass filter calculated?

Set R3 = R4 = Rf2 and C3 = C4 = 0.01 µF, then use Fc = 1 / (2π Rf2 Cf).

What supply voltage range can be used with the filter?

The filter can be powered with a supply voltage between 4 V and 18 V.

What is the precision of the internal components?

Internal components have a 1 % accuracy with a temperature coefficient of 30 ppm/°C.