NJJ3 Counting Relay Manual

NJJ3 counter relay is suitable for control circuit of AC 50Hz, rated control power supply voltage up to 240V and DC rated control power supply voltage up to 240V as a counter or counter control element.


NJJ3 Counting Relay Manual - cover page
Brand
NJJ3
Category
RELAY
Document type
User Manual
Language
Chinese
Pages
4
File format
PDF
File size
354 KB
Published
15 March, 2012
Updated
30 September, 2023
MD5 checksum
F1CF254FBBA704BF07C2582017F1E222

About this manual

This manual describes the NJJ3 counting relay, which can be used in AC 50 Hz and AC/DC control circuits with voltages up to 240 V. It details the relay's functions, counting modes, and wiring connections.

The document includes technical parameters, physical dimensions, installation guidelines, and timing diagrams for various counting and output modes, helping users configure and maintain the device. This manual is written in Chinese.

What's inside

  • Scope
  • Model and Meaning
  • Main Parameters and Technical Performance
  • Wiring Diagram
  • Physical Dimensions and Installation
  • Counting Mode Timing Diagram
  • Output Mode Timing Diagram

Specifications

Electrical life1×10
Mechanical life1×10⁷ cycles
Number of counting digits6 digits
Counting speed1‑1000 counts per second (configurable)
Mounting dimensionsW 88 mm × H 72 mm × L 97 mm

Frequently asked questions

How many counting digits does the relay support?

The relay supports 6 counting digits, shown by six red LEDs for count and six green LEDs for preset values.

How is the relay installed?

It is a panel‑mount type with dimensions W 88 mm × H 72 mm × L 97 mm and mounting hole size W 69 mm × H 69 mm.

Download PDF (354 KB)