This manual describes the installation of the DE5450 1 POWERMAX fully monitored wireless alarm control system. This system supports 16 Power Max compatible sensors, 16 Power Max compatible transmitters, 16 4-wire zone system sensors, 4 2-wire zone system sensors and 1 optional X-10 siren.
This manual provides step‑by‑step instructions for installing the PowerMax wireless alarm control system. It covers unpacking, power connection, mounting the control board on its wall‑mounted bracket, and wiring of AC transformers, RS‑232 modules and optional X‑10 sirens.
The guide also details programming of zones, compatible detectors and transmitters, diagnostic tests, battery backup procedures, and troubleshooting of common faults. Appendices list detector and transmitter configurations and offer templates for installation planning. This manual is written in Chinese.
| Operating frequency | 315 MHz (or other UHF band per local regulations) |
|---|---|
| Physical dimensions | 250 mm × 190 mm × 44 mm |
| Weight | 2 lb (≈ 905 g) without battery |
| Operating temperature range | 32 °F – 120 °F (0 °C – 49 °C) |
| Power supply | 120 VAC 60 Hz / 9 VAC 700 mA (US) or 230 VAC 50 Hz / 9 VAC 700 mA (EU) |
The system supports 29 wireless zones and one hard‑wired zone (No. 30).
Backup power can be supplied by six AA alkaline batteries (1.8 Ah) or six AA Ni‑Mn rechargeable batteries (650 mAh).