NANR NRZDC-5A Direct‑Current Resistance Quick Tester Manual

NRZDC-5A DC resistance quick test instrument is an ideal instrument for measuring the DC resistance of transformer windings, high and low voltage cables and large power capacitors and inductors. It adopts a brand-new power supply technology and has the characteristics of rapid measurement, small size, convenient operation and high measurement accuracy.


NANR NRZDC-5A Direct‑Current Resistance Quick Tester Manual - cover page
Brand
NANR
Category
Other Electronics
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
435 KB
Published
12 March, 2012
Updated
30 September, 2023
MD5 checksum
8FC0EA514E5585F4202055E800032AF7

About this manual

The NRZDC-5A is a compact, high‑accuracy direct‑current resistance tester designed for measuring transformer windings, power cables, and large inductive loads. It uses a four‑wire method with a programmable constant‑current source and a high‑precision A/D converter to provide fast, reliable resistance readings.

The manual describes the instrument’s panel layout, connection methods, data storage and printing functions, safety precautions, and troubleshooting steps, enabling users to quickly set up measurements, store up to 255 results, and print them with the built‑in mini printer. This manual is written in Chinese.

What's inside

  • Overview
  • Structure and Working Principle
  • Main Technical Features
  • Dimensions and Weight
  • Quick Start
  • Panel Description
  • Output Section
  • Display and Keyboard
  • Printing and Data Storage
  • Fault Analysis and Safety

Specifications

Test current1 A, 5 A
Accuracy±0.2 % (full scale)
Display128 × 64 dot‑matrix LCD
Resolution1 µΩ
Power supplyAC 220 V ± 10 % 50 Hz ± 2 Hz
Maximum power consumption400 W
Operating temperature0 °C ~ 40 °C
Relative humidity≤ 80 %
Dimensions400 mm × 200 mm × 425 mm
Weight11 kg
Data storage capacity255 measurements

Frequently asked questions

How many measurement results can be stored in the NRZDC-5A?

The instrument can store up to 255 measurement results.

How do I print the stored measurement data?

Press the Print key; the built‑in mini printer will print all stored data.

What happens to stored data when the instrument is powered off or reset?

Stored data is retained; it is not lost during power‑off or reset.