AUTN CYG60 Series Micro Pressure Sensor Transmitter Manual

AUTN-CYG60 micro pressure sensor/transmitter adopts silicon stacking technology, advanced micro-miniaturization manufacturing and packaging technology, high-precision integrated piezoresistive force-sensitive element, and has exquisite and ingenious micro packaging, with excellent dynamic and static characteristics.


AUTN CYG60 Series Micro Pressure Sensor Transmitter Manual - cover page
Brand
AUTN-CYG60
Document type
Product Leaflet
Language
Chinese
Pages
2
File format
PDF
File size
114 KB
Published
29 February, 2012
Updated
30 September, 2023
MD5 checksum
61BAAEF3556F54374CCD9389F11AB608

About this manual

The AUTN CYG60 series is a miniature pressure sensor transmitter designed for high‑precision measurements in research, biomedical, fluid dynamics, and other scientific applications. It features a compact package, low temperature drift, and robust construction suitable for harsh environments.

The document lists performance parameters such as measurement range (0 kPa to 6 MPa), supply voltage (10–24 VDC), output options (1.5–4.5 mV/V, 4–20 mA, 0–5 VDC), and operating temperature limits. It also includes installation notes, physical dimensions, and optional functions for customized solutions. This manual is written in Chinese.

What's inside

  • Product Overview
  • Features
  • Performance Parameters
  • Measurement Range
  • Signal Output
  • Physical Dimensions
  • Installation Guidelines
  • Applications

Specifications

Measurement range0–10 kPa, up to 6 MPa
Signal output1.5–4.5 mV/V, 4–20 mA, 0–5 VDC
Supply voltage10–24 VDC (typical 15 VDC)
Operating temperature-40 °C to 85 °C (general), -10 °C to 120 °C (special)
Accuracy (typical)0.25 % FS
Long‑term stability0.1 % FS/yr typical, 0.2 % FS/yr max
Frequency response20 kHz–1.6 MHz
DimensionsDiameter 2.54 mm, length 3.77 mm
Input impedance100 MΩ (at 50 VDC)
Maximum acceleration10 000 g
Vibration test range10–2000 Hz, sine wave, 100 g

Frequently asked questions

What is the measurement range of the AUTN CYG60 series sensor?

It can measure pressures from 0 kPa up to 6 MPa, covering ranges such as 0–10 kPa and 20 kPa.

What supply voltage does the sensor require?

The sensor operates from 10 VDC to 24 VDC, with a typical value of 15 VDC.

What output signal options are available?

It provides 1.5–4.5 mV/V, 4–20 mA, or 0–5 VDC output signals.

What are the operating temperature limits?

General models operate from –40 °C to 85 °C, while special versions can handle –10 °C to 120 °C.