This manual introduces the Haier YR0054 drinking fountain, highlighting its dual hot‑water and warm‑water design, automatic temperature control, sealed structure, and food‑grade materials that ensure safe, clean drinking water. Safety notices cover proper power connections, operating temperature limits, and warnings against unauthorized repairs.
The guide details how to install the bottle, operate hot and cold taps, perform regular cleaning, and troubleshoot common issues such as no heating or leakage. It also lists technical specifications, warranty terms, service‑center contacts, and environmental compliance information. This manual is written in Chinese.
| Rated heating power | 420 W |
|---|---|
| Power consumption | 0.55 kW·h |
| Leakage‑protection class | Class I |
| Operating ambient temperature | 10 °C – 38 °C |
The power socket must be a three‑pole grounded outlet with a leakage‑protection device.
After the machine runs for 30 minutes, unplug the power, open the drain plug, empty the water, and rinse with pure water.
The red light turns on when the water temperature is above 80 °C and turns off (or changes to green) when it exceeds 90 °C.
Check whether the heating element is burnt, verify the power switch is on, and ensure the power cord is properly connected.