Endress+Hauser Proline Promag 50P/53P User Manual

Promag 50P, 53P electromagnetic flow meters are used for bidirectional measurement of liquids with a minimum conductivity of ≥ 5 μS/cm. It can be used for acids, alkali solutions, paints, pastes, mashes, water, wastewater, etc. The flow measurement range can be up to 9600 m3/h, the fluid temperature can be up to 180 °C, and the process pressure can be up to 40 bar. It is suitable for hazardous areas and can be connected to HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, MODBUS RS485 and other control systems.


Endress+Hauser Proline Promag 50P/53P User Manual - cover page
Brand
50P/53P
Document type
User Manual
Language
English
Pages
40
File format
PDF
File size
903 KB
Published
24 February, 2012
Updated
30 September, 2023
Model
53P
MD5 checksum
FFD61E8B1129CCEABFB1B5642913A204

About this manual

The Proline Promag 50P and 53P are electromagnetic flow measuring systems designed for chemical and process applications. The manual describes the measuring principle, system design, and the two available versions – a compact unit where transmitter and sensor are combined, and a remote version with separate components.

It provides detailed information on inputs, outputs, power supply, and communication interfaces such as HART, PROFIBUS DP/PA, MODBUS RS485, and FOUNDATION Fieldbus, as well as terminal assignments, installation guidelines, and technical specifications.

What's inside

  • Measuring principle
  • System design
  • Transmitter and sensor options
  • Input and output signals
  • Communication interfaces
  • Power supply and terminal assignment
  • Installation and wiring
  • Technical specifications

Specifications

Maximum fluid temperature+180 °C
Maximum process pressure40 bar
Maximum flow measurement9600 m³/h
Velocity measuring range0.01 … 10 m/s
Status input voltage3 … 30 V DC (5 kΩ)
Power supply voltage (AC)85 … 200 V AC
PROFIBUS PA current consumption11 mA
FOUNDATION Fieldbus current consumption12 mA
PROFIBUS DP data rate9.6 kBaud … 12 MBaud
Supported MODBUS baud rates1200 – 115200 Baud

Frequently asked questions

Which communication protocols are supported by the Proline Promag 50P/53P?

The device supports HART, PROFIBUS DP/PA, FOUNDATION Fieldbus, and MODBUS RS485.

What is the maximum process temperature the flowmeter can handle?

It can operate at fluid temperatures up to +180 °C.

What power supply voltage ranges are allowed for the transmitter?

The power supply can be 85–200 V AC, 20–55 V AC, or 16–62 V DC.

Download PDF (903 KB)