NIOSH CBRN PAPR Test Procedure NPPTL-STP-CBRN-PAPR-0550

This document establishes the procedures for ensuring the level of respiratory protection provided by Chemical, Biological, Radiological, and Nuclear (CBRN) Protection requirements for Powered Air-Purifying Respirator (PAPR).


NIOSH CBRN PAPR Test Procedure NPPTL-STP-CBRN-PAPR-0550 - cover page
Brand
NIOSH
Document type
Application Note
Language
English
Pages
29
File format
PDF
File size
297 KB
Published
16 February, 2012
Updated
30 September, 2023
MD5 checksum
8EC534D0B32915D553AD04F928939D19

About this manual

This document establishes the procedures for testing CBRN powered air‑purifying respirators (PAPRs) to ensure they meet certification standards for chemical, biological, radiological, and nuclear protection. It details the test conditions, equipment, and acceptance criteria used during dynamic testing with sarin (GB) vapor.

The procedure lists required test equipment such as the SMARTMAN headform, leak detector TDA‑99M, MINICAMS gas chromatograph, syringe pump, flow‑temperature‑humidity control system, exposure chamber, breather pump, mass flow controllers, and ambient air analyzer. It also specifies the number of tight‑fitting and loose‑fitting PAPRs needed for qualification and remainder testing.

What's inside

  • Purpose
  • General
  • Equipment
  • Required Tight Fitting PAPR Quantities
  • Required Loose Fitting PAPR Quantities
  • Test Title
  • Revision History

Frequently asked questions

What is the purpose of the NPPTL‑STP‑CBRN‑PAPR‑0550 document?

It establishes the procedures for testing CBRN powered air‑purifying respirators against sarin vapor to verify compliance with certification standards.

How many tight‑fitting PAPRs are required for GB Live Agent Testing?

Three complete tight‑fitting PAPR systems are required.