NIOSH CET-APRS-STP-CBRN-0407 Standard Test Procedure

This STP describes the Determination of CBRN Base Gases (Ammonia) Service Life Test; Air-Purifying Escape Respirators test in sufficient detail that a person knowledgeable in the appropriate technical field can select equipment with the necessary resolution, conduct the test and determine whether or not the product passes the test.


NIOSH CET-APRS-STP-CBRN-0407 Standard Test Procedure - cover page
Brand
NIOSH
Document type
Other
Language
English
Pages
9
File format
PDF
File size
49 KB
Published
16 February, 2012
Updated
30 September, 2023
MD5 checksum
9BCAA5CB9EB5201085BE8276A99DC44C

About this manual

This document defines the procedure (CET‑APRS‑STP‑CBRN‑0407) used by NIOSH to evaluate the service life of air‑purifying escape respirators when exposed to ammonia base gases. It specifies the equipment, test conditions, and acceptance criteria required to meet 42 CFR Part 84 certification standards.

The procedure outlines required test equipment (e.g., Miller Nelson Model 401 flow‑temperature‑humidity system, EdgeTech Dew Prime II hygrometer, Air‑Sentry IMS ammonia analyzer), safety precautions, calibration requirements, and detailed steps for setting up the test chamber, establishing ammonia concentrations, recording resistance measurements, and determining pass/fail outcomes.

What's inside

  • Purpose
  • General
  • Equipment and Material
  • Testing Requirements and Conditions
  • Procedure
  • Pass or Fail Criteria
  • Records and Test Sheets
  • Attachments
  • Revision History

Specifications

Miller Nelson Model 401 flow capacity20 to 200 L/min ±2%
EdgeTech Dew Prime II hygrometer temperature range-50 °C to 130 °C ±0.2 °C
Air‑Sentry IMS ammonia analyzer range (Model 10R‑NH3‑4000M)1 to 3000 ppm ±0.1 % FS
Download PDF (49 KB)