This document introduces the 360-degree prisms of Leica Geosystems TCA total station, including GRZ4 360-degree prism, GRZ121 360-degree precision prism and GRZ101 360-degree micro prism.
This Leica Geosystems AG accessory leaflet describes 360° prisms for TCA measuring robot total stations. It covers the GRZ4, GRZ121, and GRZ101 prism models and explains that the six-prism hexagonal design returns measurement beams from any direction.
The leaflet lists accuracy figures for each prism, notes the GAD103 adapter for Wild Stub prism poles, and explains how to identify genuine Leica prisms using the silver foil label while warning against counterfeit products. This manual is written in Chinese.
| GRZ4 overall accuracy | 5mm |
|---|---|
| GRZ4 direct aiming accuracy | better than 2mm |
| GRZ121 elevation measurement accuracy | 2mm |
| GRZ101 highest point measurement accuracy | 1.5mm |
The overall accuracy is 5mm.
Check the silver foil label on the product, which states the manufacturer is Leica Geosystems AG.
The GAD103 adapter fits the micro prism to any Wild Stub prism pole.
Elevation measurement accuracy can reach 2mm.