SUNSTAR KHM-HC2 Humidity Measurement Module Datasheet


SUNSTAR KHM-HC2 Humidity Measurement Module Datasheet - cover page
Brand
KHM-HC2
Category
sensor
Document type
Datasheet
Language
Chinese
Pages
11
File format
PDF
Updated
13 October, 2026
MD5 checksum
11386E54226ACA779B2FE3FB5B6A4F5A

About this manual

The SUNSTAR KHM-HC2 is a humidity measurement module applied in electronics, textiles, warehousing, tobacco, pharmaceuticals, meteorology, and products such as hygrometers, humidifiers, dehumidifiers, air conditioners, and microwave ovens.

It uses a high-polymer humidity capacitive element (HS1101), operates on DC5V±5% at 2mA, and measures humidity from 20%RH to 90%RH with ±5%RH accuracy at 25°C. This manual is written in Chinese.

What's inside

  • Application scope
  • Model specifications
  • Electrical parameters
  • Standard test conditions
  • Stability and reliability tests
  • Usage precautions

Specifications

Humidity sensitive elementHigh-polymer humidity capacitive HS1101
Supply voltageDC5V±5%
Current consumption2mA
Operating temperature range0–60°C
Humidity detection range20–90%RH
Humidity detection accuracy±5%RH at 25°C

Frequently asked questions

What is the supply voltage for the KHM-HC2 module?

The module requires a supply voltage of DC5V±5%.

What is the humidity detection accuracy?

Humidity detection accuracy is ±5%RH at a temperature of 25°C.

What is the operating temperature range?

The operating temperature range is 0°C to 60°C.