This document provides instructions for the use of the Rat Leptin Receptor (LEPR) ELISA Kit manufactured by Uscn Life Science Inc. Wuhan. The kit is intended for in vitro research use and is used to quantitatively measure the concentration of LEPR in rat serum, plasma, or other related biological fluids.
About this manual
This manual provides detailed instructions for using the USCNK E0083Ra ELISA kit to quantify rat leptin receptor (LEPR) in biological samples. It lists all reagents supplied, required equipment, and step‑by‑step procedures for plate preparation, sample incubation, detection, and data analysis.
Key points include sample collection and storage guidelines, incubation temperatures, washing protocols, and safety precautions for handling acidic stop solution. The document also specifies the assay’s detection range and limit of detection, ensuring reliable quantitative results. This manual is written in Chinese.
What's inside
- Reagents and Materials
- Sample Collection and Storage
- Assay Procedure
- Plate Washing
- Data Analysis
- Safety Warning
Specifications
| Detection range | 0.78 ng/mL – 50 ng/mL |
|---|
| Limit of detection | 0.45 ng/mL |
|---|
| Plate type | 96‑well pre‑coated plate |
|---|
| Incubation temperature | 37 °C |
|---|
| Sample storage temperature | -20 °C or -80 °C |
Frequently asked questions
What is the detection range of the ELISA kit?
The kit can detect LEPR concentrations from 0.78 ng/mL up to 50 ng/mL.
How should serum samples be stored before testing?
After centrifugation, serum should be stored at –20 °C or –80 °C until analysis.
What incubation time and temperature are required for the plate coating step?
Incubate the coated plate at 37 °C for 2 hours before adding detection reagents.
What safety precaution is mentioned for the stop solution?
The stop solution contains sulfuric acid; avoid contact with skin, eyes, clothing, and handle with care.