This manual describes the EUROLIVE B512DSP speaker in detail, including safety instructions, ventilation, ground, placement, power switch and prohibition of operation, maintenance and cleaning.
This manual begins with important safety instructions, emphasizing proper ventilation, grounding, and the prohibition of opening the unit without professional assistance. It also details the recommended installation environment, power‑on procedures, and the use of compatible racks and accessories.
The document then describes the front‑panel controls, input and output connectors, and the built‑in DSP functions such as EQ, high‑pass filter, noise gate, and automatic turn‑off. Application examples show how to connect microphones, mixing consoles, and multiple B512DSP units for larger PA setups, followed by a full technical data sheet covering power, frequency response, SPL, and power‑supply requirements. This manual is written in Chinese.
| Maximum Power Consumption | 650 W |
|---|---|
| High‑frequency RMS Power | 80 W @ 8 Ω |
| Maximum SPL | 127 dB @ 1 m |
| Frequency Range | 45 Hz – 20 kHz |
| MIC/LINE Input Impedance | 27 kΩ |
| Power Supply Voltage (US/Canada) | 120 V ~ 60 Hz |
The CLIP‑LED lights when the input signal level exceeds the set threshold, indicating that the level should be reduced to avoid distortion.
Connect the LINE OUT jack of one B512DSP to the MIC/LINE input of the next unit; repeat for additional speakers, noting that the input impedance will decrease with each added unit.