SUN5TAR CRS03 Gyroscope Datasheet

The Silicon Sensing Systems Japan Rate Gyroscope CRS03 is an angular velocity sensor that uses Silicon MEMs technology and is known for its good performance under severe vibration/shock and temperature change. It outputs analog DC voltage proportional to the angular velocity, centered at approximately 2.5V dc with a supply voltage of 5Vdc.


SUN5TAR CRS03 Gyroscope Datasheet - cover page
Brand
Rate
Category
Other Electronics
Document type
Datasheet
Language
English
Pages
3
File format
PDF
File size
473 KB
Published
15 November, 2011
Updated
28 September, 2023
MD5 checksum
12FECE030478F71D791BE947A6B16A9E

About this manual

The CRS03 is a silicon‑MEMS gyroscope offering stable analog DC output proportional to angular velocity, with low temperature drift and good repeatability. It is used in automotive ESP systems, GPS‑aided direction controllers, antenna stabilizers, RC helicopters, autonomous guided vehicles, marine autopilots, inertial control units, bipedal robots, and telematics.

Key specifications include a 5 V supply, a rate range of up to ±100 deg/sec (±200 deg/sec for the CRS03‑04 variant), a scale factor of 20 mV/(deg/sec), operating temperature from –40 °C to +85 °C, and a bandwidth greater than 10 Hz. The device requires a low‑pass filter on the output to reduce internal noise for anti‑aliasing.

What's inside

  • Product Description
  • Applications
  • Electrical Specifications
  • Mechanical Dimensions
  • Performance Characteristics
  • Version Table
  • Usage Notes

Specifications

Rate range0 to ±100 deg/sec (CRS03‑01/02)
Scale Factor (SF)20 mV/(deg/sec) (CRS03‑01/02)
Supply Voltage (Vdd)5.00 V ±0.25 V DC
Operating Temperature-40 °C to +85 °C
Bandwidth>10 Hz (up to 50 Hz for CRS03‑11)
Quiescent Noise<1 mV rms (up to 10 Hz)
Dimensions29 mm × 29 mm × 18.4 mm
Output Impedance100 Ω

Frequently asked questions

What supply voltage does the CRS03 require?

The CRS03 operates from a 5.00 V DC supply with a tolerance of ±0.25 V.

What temperature range can the CRS03 operate in?

It can operate from –40 °C up to +85 °C (CRS03‑11 up to +60 °C).

Is a filter needed on the gyroscope output?

A hardware low‑pass filter is recommended to attenuate internal transistor amplifier noise for anti‑aliasing.

Download PDF (473 KB)

More Rate Manuals


View all Rate manuals →