YUDO STEC-NA2 Error 021: Product take-out mode (MDW) is not used.

YUDO STEC-NA2 · taken from the manufacturer’s manual, pages cited

Error code021

Product take-out mode (MDW) is not used. The manual's first action is: “Cannot perform the product-side arm operation.”

Model
YUDO STEC-NA2
Display shows
Product take-out mode (MDW) is not used. (021)
Type
Error code
Source
Manual p. 44

What 021 means

Product take-out mode (MDW) is not used. p. 44

Common causes

  • Product take-out mode (MDW) is not used. p. 44
  • Although cycle start (RY3) is output from the take-out machine, the injection molding machine mold open completion (MO) is not OFF. p. 44

What to do

  1. Cannot perform the product-side arm operation. p. 44
  2. Check the output of the cycle start signal and the operating state of the relay circuit, the mold open completion circuit of the injection molding machine, and the wiring of the interlock signal between the take-out machine and the injection molding machine. p. 44

Before you service the product, read the safety instructions in the manual p. 9.

If 021 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact YUDO service.

This page summarises what the manufacturer’s manual says about 021; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with YUDO. Found a mistake? Report an error.