Viessmann Vitodens 111-W Error 74: Burner locked out.

Viessmann Vitodens 111-W water heater · taken from the manufacturer’s manual, pages cited

Fault code74

Fault 74 means the burner is locked out because system pressure is too low. The manual's first action is: “Top up with water. Vent the system. If the fault occurs repeatedly: Check system pressure sensor with external pressure gauge. Check diaphragm expansion vessel pre-charge pressure. Check settings for set system pressure and range.”

Model
Viessmann Vitodens 111-W
Display shows
Burner locked out. (74)
Type
Fault code
Source
Manual p. 71

What 74 means

Burner locked out. p. 71

Common causes

  • System pressure too low p. 71

What to do

  1. Top up with water. Vent the system. If the fault occurs repeatedly: Check system pressure sensor with external pressure gauge. Check diaphragm expansion vessel pre-charge pressure. Check settings for set system pressure and range. p. 71

If 74 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Viessmann service.

This page summarises what the manufacturer’s manual says about 74; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Viessmann. Found a mistake? Report an error.