Error codeErr 1
Battery temperature exceeds 50°C. The manual's first action is: “If error persists and charging does not resume, replace sensor, and power-up by entering and leaving the setup menu.”
- Model
- Victron Energy MPPT 150/70 CAN-bus
- Display shows
- Battery temperature too high (>50°C) (Err 1)
- Type
- Error code
- Source
- Manual p. 18
What Err 1 means
Battery temperature too high (>50°C) p. 18
Common causes
- This error is also due to a bad/corroded battery- pole to which this sensor is screwed on, or to, a faulty sensor. p. 18
- This error will auto-reset after temperature has dropped. p. 18
What to do
- If error persists and charging does not resume, replace sensor, and power-up by entering and leaving the setup menu. p. 18
If Err 1 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Victron Energy service.
This page summarises what the manufacturer’s manual says about Err 1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Victron Energy. Found a mistake? Report an error.